Specialized Meters

There are hundreds of specialized test instruments used today for many different applications. 

Capacitance Meters are designed to check the quality of the capacitor and also determine the value of unknown capacitors, in or out of the circuit. It can also identify power factor values, leakage and open circuits. 

Light/LUX Meters are designed to measure illumination. 

TES Test Instruments provides various types of test instruments from temperature sensor, to sound level and to automotive meter.



TES-1300 Digital Thermometer

View larger image

This TES-1300 is a digital thermometer for use with any K-type thermocouple as temperature sensor. Temperature indication follows National Bureau of Standards and IEC584 temperature/voltage tables for K-type thermocouples.

SPECIFICATION:

  • Numerical Display: 3 1/2 digital LCD 14mm height; With maximum reading of 1999, and indications or minus sign "-", data hold, max hold, T1, T2, T1-T2, °C, °F and low battery
  • Measurement Range: -50°C to 1300°C or -50°F to 1999°F
  • Resolution: 0.1°C, 1°C, 0.1°F, 1°F
  • Maximum Voltage at Thermocouple Input: 60Vdc or 24Vrms AC
  • RF Field Derating: Storing RF fields and low frequency adversely affect accurate measurement
  • Operating Temperature and Humidity: 0°C to 50°C (32°F to 122°F) 10 to 80% RH
  • Storage Temperature and Humidity: -10°C to 60°C (14°F to 140°F) 10 to 70% RH
  • Basic Accuracy: @23±5°C Calibration; Accuracy are ±(% of reading + degree) at 18°C to 18°C with relative humidity up to 80%

 

 
TES-1350A Sound Level Meter

View larger image

The TES-1350A Sound Level Meter is used to measure the amount or intensity of a sound in a certain environment to ensure that the measurement requirements for industrial safety offices and sound quality control in various environments are met. This unit is designed according to the IEC651, ANSI S1.4 for Sound Level Meters.

SPECIFICATION:

  • Numerical Display: 4-digit digital LCD with 0.1dB resolution and a display period of 0.5 seconds; With indications on measuring unit, when readout is out of range, maximum hold and low battery
  • Measuring Level Range: Lo - 35 to 100dB; Hi - 65 to 130dB
  • Frequency Range: 31.5Hz to 8Hz
  • Microphone: 1/2 inch Electric Condenser Microphone
  • Accuracy: ±2.0dB
  • Time Weighting: Fast (125ms), Slow (1s)
  • Dynamic Range: 65dB
  • Alarm Function: "OVER" is displayed when input is out of range
  • Maximum Hold: Hold readings, with decay <1dB/3 minutes
  • Calibration: Electrical calibration with the internal oscillator (1kHz sine wave)
  • AC Output: 0.65Vrms at full scale; Output impedance approximately 600 ohms
  • DC Output: 10mV/dB; Output impedance approximately 100 ohms
  • Power supply: One 9V Battery 006P or IEC 6F22 or NEDA 1604
  • Power Life: About 50hrs. (alkaline cell)
  • Operating Temperature: 0 to 40°C (32°F to 140°F)
  • Operating Humidity: 10 to 90% RH
  • Storage Temperature: -10 to 60°C (14°F to 140°F)
  • Storage Humidity: 10 to 75% RH
  • Dimension (LxWxH): 240mm x 68mm x 25mm
  • Weight: 210g (including battery)
  • Accessories: 9V battery, carrying case, screwdriver, instruction manual, 3.5? plug, windscreen

 

 
TES-1302 Digital Thermometer

View larger image

The TES-1302 Digital Thermometer is used with any K-type thermocouple as temperature sensor. Temperature indication follows National Bureau of Standards and IEC584 temperature/voltage tables for K-type thermocouples.

SPECIFICATION:
  • Numerical Display: 3 1/2 digital LCD 14mm height; With maximum reading of 1999, and indications or minus sign "-", data hold, max hold, T1, T2, T1-T2, °C, °F and low battery
  • Measurement Range: -50°C to 1300°C or -50°F to 1999°F
  • Resolution: 1°C, 1°F
  • Maximum Voltage at Thermocouple Input: 60Vdc or 24Vrms AC
  • RF Field Derating: Storing RF fields and low frequency adversely affect accurate measurement
  • Operating Temperature and Humidity: 0°C to 50°C (32°F to 122°F) 0 to 80% RH
  • Storage Temperature and Humidity: -10°C to 60°C (14°F to 140°F) 0 to 70% RH
  • Basic Accuracy: @23±5°C Calibration; Accuracy are ±(% of reading + degree) at 18°C to 18°C with relative humidity up to 80%

 

 
TES-1550 Digital Inductive Tach/Dwell Multimeter (for Automotive)

View larger image

The TES-1550 TES-1550 Digital Inductive Tach/Dwell Multimeter is a hand-held digital multimeter designed to measure DC and AC voltage, DC and AC current, frequency, resistance, audible continuity, diode test, capacitance, dwell and engine RPM via an inductive (clamp-on) jaw. It comes with auto-power off and water-proof ABS housing.

SPECIFICATION:
  • Numerical Display: 3-3/4 digit digital LCD; With maximum reading of 3999 with bar graph; With indications such as measurement values, unit symbols, decimal point, polarity, over range and low battery.
  • Dimension (LxWxH): 184mm x 82mm x 42mm
  • Weight: 360g (Approximate)
  • Power Source: 2 pcs. of "AA" of 1.5V battery (400hrs. approximate)
  • Accessories: instruction manual, thermo case TP-E06, spare fuse (0.5A/250V) and test leads
  • Tachometer (Manual)
    • Tacho: 10 to 10,000 RPM
    • Accuracy: ± (2% reading + 1 digit)
    • Resolution: 10 RPM
    • Overload Protection: 30Vdc
  • Dwell (Manual)
    • Range: %/4 cylcle/6 cycle/8 cycle
    • Accuracy: ± (2% reading + 1 digit)
    • Resolution: 1% (1°)
    • Overload Protection: 125Vdc
  • Current(DC/AC) (Autorange/Manual)
    • Range: 40m/400m/20A (DC/AC)
    • Accuracy: 
      40m/400mA: DC ± (1.0% reading + 1 digit)
      AC ± (1.5% reading + 3 digits)
      20A: DC ± (1.5% reading + 2 digits)
      AC ± (2.0% reading + 5 digits)
    • Resolution: 0.01mA/0.1mA/0.01A
    • Overload Protection: 0.5A/250V Fuse for 40mA~400mA; 20A/600V high energy fuse for 20A range
  • Voltage(DC/AC) (Autorange/Manual)
    • Range: 400m/4/40/400, 750V(AC), 1000V(DC)
    • Accuracy: DC ± (0.5% reading + 1 digit)
    • Resolution: 0.1mV/0.001V/0.01V/0.1V/1V
    • Overload Protection: 1100Vdc/800Vac
  • Frequency (Autorange)
    • Range: 100/1K/10K/100K/500K
    • Accuracy: ± (0.1% reading + 2 digits)
    • Resolution: 0.01Hz/0.1Hz/1Hz/10Hz/100Hz
    • Sensitivity: 100mV/1V/10V
    • Overload Protection: 500Vdc/350Vac
  • OHMs(Resistance) (Autorange/Manual)
    • Range: 400/4K/40K/400K/4M/40M
    • Accuracy: ± (0.8% reading + 3 digit); ± (1.5% reading + 5 digits) for 40M? range
    • Resolution: 0.1µ/0.001kµ/0.01kµ/0.1kµ/0.001Mµ/0.01Mµ
    • Overload Protection: 500Vdc/350Vac
  • Audible Continuity
    • Continuity Beeper: ?40?
    • Open Circuit Voltage: ?0.5V
    • Resolution: 0.1µ
    • Overload Protection: 500Vda/350Vac
  • Capacitance (Autorange/Manual)
    • Range: 4n/40n/400n/4µ/40µF
    • Accuracy: ± (1.5% reading + 10 digits); ± (1.5% reading + 20 digits) for 4nF
    • Resolution: 0.001nF/0.01nF/0.1nF/0.001µF/ 0.01µF
    • Overload Protection: 500Vdc/350Vac
  • Diode Test
    • Accuracy: ± (1% reading + 2 digits)
    • Resolution: 1mV
    • Overload Protection: 500Vdc/350Vac

 

 
<< Start < Prev 1 2 Next > End >>

Page 2 of 2